Relative-Value Tables

The Fire Suppression Rating Schedule (FSRS) lists a large number of items a community should have to fight fires effectively. The Schedule assigns credit points for each item. Using those credit points and various formulas, ISO calculates a total FSRS score on a scale of 0 to 100.

This page will help you understand how adding certain pieces of equipment will affect your community's FSRS score.

FSRS Tables 512.A, 544.A, and 544.B list equipment for which you can get credit, together with the number of credit points you can get per unit of equipment and the total number of credit points available for each item. For example, in Table 512.A, you'll find that you need a 300-gallon booster tank. The table shows that you get 1 credit point for each 10 gallons of capacity in your booster tank. You can get up to a total of 30 credit points if you have the full 300-gallon tank.

Similarly, you need 200 feet of booster hose. You get 3 points for each 50 feet, up to a total of 12 points if you have the full 200 feet.

If you have all the items in Table 512.A, you can get a maximum of 654 credit points. What does that mean for your FSRS score?

In the following table, you'll see that the maximum effect for all items from Table 512.A — if you were to get all 654 available credit points — would be to add 10.00 points to your FSRS score. The effect of adding any one item from Table 512.A is in proportion. For example, if you were to get the full 30 credit points for a 300-gallon booster tank, you could get 4.59% of the 10.00 points added to your FSRS score (because 30 ÷ 654 = 4.59%). So for the booster tank, you could get a maximum of 0.46 points added to your FSRS score (because 10.00 x 4.59% = 0.46, rounded to two decimal places).

The following tables show the same calculation for all the equipment listed in Tables 512.A, 544.A, and 544.B.

 

Relative Value of Pumper Equipment and Hose (Table 512.A)

Equipment & Hose
Needed
Points Credit/Unit
Total Points Possible
Percentage of Available Points
Maximum Points Added to FSRS Preliminary Score
Booster tank 300 gal. 1/10 gal. 30 4.59% 0.46
Hose: booster 200 feet 3/50 12 1.83% 0.18
Hose: 1-1/2" carried 400 feet 3/50 24 3.67% 0.37
Hose: 1-1/2" spare 200 feet 2/50 8 1.22% 0.12
Hose: 2-1/2" spare 200 feet 3/50 12 1.83% 0.18
Heavy-stream appliance
(1,000 gpm)
1 100 100 15.29% 1.53
Distributing nozzle 1 5 5 0.76% 0.08
Foam nozzle
(1-1/2" minimun)
1 4 4 0.61% 0.06
Foam: carried 10 gal. 3/5 gal. 6 0.92% 0.09
Foam: spare 15 gal. 2/5 gal. 6 0.92% 0.09
Nozzles: 2-1/2" playpipe with shutoff 2 20 40 6.12% 0.61
Nozzles: 2-1/2" straight stream & spray 2 30 60 9.17% 0.92
Nozzles: 1-1/2" straight stream & spray 2 10 20 3.06% 0.31
Breathing equipment
(30-min. minimum)
4 16 64 9.79% 0.98
Breathing equipment extra cylinders 4 4 16 2.45% 0.25
Salvage covers 2 2 4 0.61% 0.06
Handlight
(4V wet, 6V dry)
2 2 4 0.61% 0.06
Hose clamp 1 4 4 0.61% 0.06
Hydrant hose gate
(2-1/2")
1 4 4 0.61% 0.06
Burst hose jacket
(2-1/2")
1 4 4 0.61% 0.06
Gated wye
(2-1/2" x 1-1/2" x 1-1/2")
1 4 4 0.61% 0.06
Radio: mounted 1 32 32 4.89% 0.49
Radio: portable 1 16 16 2.45% 0.25
Ladder: 12- or 14-ft. roof 1 10 10 1.53% 0.15
Ladder: 24-ft. extension 1 15 15 2.29% 0.23
Annual test: pumper 1 100 100 15.29% 1.53
Annual test: hose 1 50 50 7.65% 0.77
Totals: 654 100% 10.00
  

 

Relative Value of Equipment for a Ladder Company (Tables 544. A and 544.B)

Equipment & Hose
Needed
Points Credit/Unit
Total Points Possible
Percentage of Available Points
Maximum Points Added to FSRS Preliminary Score
Large spray nozzle
(500-gpm minimum)
1 16 16 2.04% 0.10
Breathing equipment
(30-min. minimum)
6 16 96 12.24% 0.61
Breathing equipment extra cylinders 6 4 24 3.06% 0.15
Salvage covers 10 2 20 2.55% 0.13
Electric generator
(2500 watts)
1 25 25 3.19% 0.16
Floodlight
(500 watts)
3 4 12 1.53% 0.08
Smoke ejector 1 20 20 2.55% 0.13
Oxyacetylene cutting unit 1 20 20 2.55% 0.13
Power saw 1 20 20 2.55% 0.13
Handlight
(4V wet, 6V dry)
4 2 8 1.02% 0.05
Hose roller (equipment hoist) 1 4 4 0.51% 0.03
Pike pole
(plaster hook):
6 ft.
2 2 4 0.51% 0.03
Pike pole
(plaster hook): 8 ft.
2 2 4 0.51% 0.03
Pike pole
(plaster hook): 12 ft.
2 2 4 0.51% 0.03
Radio: mounted 1 32 32 4.08% 0.20
Radio: portable 1 16 16 2.04% 0.10
Ladder: 10-ft. collapsible 1 4 4 0.51% 0.03
Ladder: 14-ft. extension 1 5 5 0.64% 0.03
Ladder: 16-ft. roof 1 20 20 2.55% 0.13
Ladder: 20-ft. roof 1 20 20 2.55% 0.13
Ladder: 28-ft. extension 1 20 20 2.55% 0.13
Ladder: 35-ft. extension 1 20 20 2.55% 0.13
Ladder: 40-ft. extension 1 20 20 2.55% 0.13
Elevated stream device 1 100 100 12.76% 0.64
Aerial ladder/elevating platform 1 200 200 25.51% 1.28
Annual test (aerial/platform) 1 50 50 6.38% 0.32
Totals: 784 100% 5.00

 

Relative Value of Equipment for a Service Company (Table 544. A)

Equipment & Hose
Needed
Points Credit/Unit
Total Points Possible
Percentage of Available Points
Maximum Points Added to FSRS Preliminary Score
Large spray nozzle
(500-gpm minimum)
1 16 16 4.79% 0.24
Breathing equipment
(30-min. minimum)
6 16 96 28.74% 1.44
Breathing equipment extra cylinders 6 4 24 7.19% 0.36
Salvage covers 10 2 20 5.99% 0.30
Electric generator
(2500 watts)
1 25 25 7.49% 0.37
Floodlight
(500 watts)
3 4 12 3.59% 0.18
Smoke ejector 1 20 20 5.99% 0.30
Oxyacetylene cutting unit 1 20 20 5.99% 0.30
Power saw 1 20 20 5.99% 0.30
Handlight
(4V wet, 6V dry)
4 2 8 2.40% 0.12
Hose roller
(equipment hoist)
1 4 4 1.20% 0.06
Pike pole
(plaster hook):
6 ft.
2 2 4 1.20% 0.06
Pike pole
(plaster hook): 8 ft.
2 2 4 1.20% 0.06
Pike pole
(plaster hook): 12 ft.
2 2 4 1.20% 0.06
Radio: mounted 1 32 32 9.58% 0.48
Radio: portable 1 16 16 4.79% 0.24
Ladder: 10-ft. collapsible 1 4 4 1.20% 0.06
Ladder: 14-ft. extension 1 5 5 1.50% 0.07
Totals: 334 100% 5.00